logo

Deterioration prediction of metallic components of a Pressure Regulatory Station by implementing the Markov chain method

Published 2020-04-06
Articles

Abstract

A Pressure Reducing Station (ERP) serves to control the service pressure and ensure the correct operation of aqueduct networks in a given sector. In the ERPs, structure, the steel pipes and fittings are exposed to corrosion and therefore to faster deterioration. That is why, based on current conditions, a method was proposed to predict this deterioration, and achieve a better maintenance management and rehabilitation of these elements.

Categories

Authors

  • César Augusto García Ubaque

    Universidad Distrital Francisco José de Caldas

  • Ferney Camilo Jiménez Beltrán

  • Milton Mena Serna

References

Arafin, M. & Szpunar, J., 2009. A Markov chain - Monte Carlo model for intergranular stress corrosion crack propagation in polyscrystalline materials. Materials, Science and Engineering, Volumen 513-514, pp. 254-266.

Bai, L., Jiang, K. & Gao, L., 2018. The Influence and Mechanism of Residual Stress on the Corrosion Behavior of Welded Structures. Materials Research, jul.21(5).

Bedoya, J. & Barrera, M., 2006. Convergencia de las cadenas de Markov. Scientia et Technica, 3(32).

Cabrera-de la Cruz, D., Patiño, C. & Galván-Martínez, R., 2018. Análisis de la corrosión de uniones por soldadura fuerte de compósitos matriz cobre. Matéria (Río de Janeiro), jul.23(2).

Clemente, J. J., 2003. Modelos de predicción del deterioro en sistemas de gestión de puentes. Valencia: Universidad Politécnica de Valencia.

Empresa de Acueducto y Alcantarillado de Bogotá, 2003. Diseño de estaciones reductoras de presión para las redes de distribución de acueducto, Bogotá: EAAB.

Empresa de Acueducto y Alcantarillado de Bogotá, 2006. Protección de tuberías en redes de acueducto y alcantarillado, Bogotá: EAAB.

IRIM, 2018. Especial mantenimiento basado en condición. Madrid: RENOVETEC.

Lara, A. M., s.f. Universidad de Granada. http://www.ugr.es/~bioestad/_private/cpfund10.pdf

Mamlouk, M. S., 2009. Acero. En: Materiales para ingeniería civil. Madrid: Pearson Prentice Hall.

Micevski, T., Kuczera, G. & Coombes, P., 2002. Markov model for storm water pipe. Journal of infraestructure systems, 8(2), pp. 49-56.

Opel, O. y otros, 2018. Corrosion in heating and cooling water circuits - A field study. Energy Procedia, Volumen 155, pp. 359-366.

Ren, L. y otros, 2018. Pipeline corrosion and leakage monitoring based on the distributed optical fiber sensing technology. Measurement, Volumen 122, pp. 57-95.

Saucer, P. W. & Riveros, G. A., 2009. A system for collecting and compiling condition data for hidraulic steel structures for us in the assessment of risk and reliability an prioritization of manteinance and repairs. Washington D.C.: US Army Corp of Engineers.

Sinha, S. K., Angkasuwansiri, T. & Thomasson, R., 2010. Background. En: Predicting the remaining economic lif of wastewater pipes. London: IWA Publishing.

Tang, J., Brouste, A. & Tsui, K., 2015. Some improvements of wind speed Markov chain modeling. Renewable Energy, Volumen 81, pp. 52-56.