logo

Design of an internet of things (IoT) system for blood pressure monitoring

Published 2021-01-06
Articles

Abstract

This article describes the design and building processes of an IoT biomedical equipment for monitoring the blood pressure of patients at their place of residence. The equipment, easy to operate, can be used directly by the patient after receiving a brief instruction from healthcare personnel. In this way, the states of agitation and stress that usually affect this physiological variable are reduced. In the prototype building, six design stages are incorporated, ranging from the electronic circuitry required for analog signal acquisition and conditioning, to the inter-connectivity of devices and data transfer to the cloud proposed by the IoT model. Validation tests and experiments suggest that the prototype has the potential to provide a solution to monitoring blood pressure at home, reducing the displacement of patients to hospital centers.

Categories

Authors

  • Alejandro Quiroz Estrada

    Politécnico Jaime Isaza Cadavid

  • Gustavo Alonso Acosta Amaya

    Politécnico JIC

  • Róbinson Alberto Torres Villa

    Universidad EIA

References

Batista, O., Del Rey, R., Ramos, J., Ruso, R. (2001). Una implementación efectiva del método oscilométrico para la medición de la presión arterial. Memorias II Congreso Latinoamericano de Ingeniería Biomédica. La Habana, Cuba. https://docplayer.es/45718453-Una-implementacion-efectiva-del-metodo-oscilometrico-para-la-medicion-de-la-presion-arterial.html

Bose, J., Das, K., Sahni, N. (2018). Web APIs for Internet of Things. Doi: 10.1109/ICACCI.2018.8554612

Champaneria, T., Nakhuva, B. (2015). Study of varius Internet of things plataforms. International Journal of Computer Science & Engineering Survey (IJCSES) Vol.6, No.6

Claus, T. (2016). APIs Para Dummies, Edicion limita IBM. Hoboken, NJ: John Wiley & Sons, Inc.

Cobos, A. (2016). Diseño e implementación de una arquitectura IoT basada en tecnologías Open Source. (Tesis en Master Universitario De Ingeniería De Telecomunicación), Departamento de Ingeniería Telemática, Escuela Técnica Superior De Ingeniería, Universidad de Sevilla, Sevilla.

Core electronics. (2018). Startup with Onion omega 2. Retrieved from: https://core-electronics.com.au/tutorials/onion/onion-omega-2-how-to-run python-script-on-startup-boot.html

Cuesta, A. (2004), Medición de la tensión arterial, errores más comunes. (Trabajo investigativo), Departament d’Infermeria, Universiat de Valéncia, Valencia.

Fluke. (2019). BP Pump 2 NIBP Blood Pressure Simulator. https://www.flukebiomedical.com/products/biomedical-test-equipment/patient-monitor-simulators/bp-pump-2-nibp-blood-pressure-simulator

Fundación BBVA. (2009). Libro de la salud cardiovascular del Hospital Clínico San Carlos y de la Fundación BBVA, 1.a edición. Bilbao, Editorial Nerea, S. A.

Gómez, M., Ondelholf, D., Teernstra, L. (2014). ThingSpeak an API and Web Service for the Internet of Things. https://www.semanticscholar.org/paper/ThingSpeak-–-an-API-and-Web-Service-for-the-of-Maureira/5dcd7d5c5a6e30aa5fa3bc2fbcbf2caa5d2e0798#paper-header

González, J. U., Olvera, D. J. (2013). Diseño y construcción de un sistema de monitoreo de signos vitales. (Tesis en Pregrado De Ingeniería en comunicaciones y Electrónica), Departamento De Ingeniería en comunicaciones y Electrónica, Instituto Politécnico Nacional, Escuela Superior De Ingeniería Mecánica y Eléctrica, México D.F.

Industria y Comercio. (2019). Organización internacional de métrologia legal (OIML). Disponible en: https://www.sic.gov.co/oiml

Lehman, L. H. et al. (2015). "A Physiological Time Series Dynamics- Based Approach to Patient Monitoring and Outcome Prediction," in IEEE Journal of Biomedical and Health Informatics, vol. 19, no. 3, pp. 1068-1076.

Loureiro, R.(2015). Estudio plataformas IoT, Universitat Oberta de Catalunya. http://openaccess.uoc.edu/webapps/o2/bitstream/10609/42812/6/rloureiroTFC0615memoria.pdf

Mathworks. (2020). React to channel activity with notification from IFTTT. Disponible en: https://www.mathworks.com/help/thingspeak/use-ifttt-to-send-text-message-notification.html

Nasiri, S., Sadoughi, F., Tadayon, M. H., & Dehnad, A. (2019). Security Requirements of Internet of Things-Based Healthcare System: a Survey Study. Acta informatica medica: AIM: journal of the Society for Medical Informatics of Bosnia & Herzegovina: casopis Drustva za medicinsku informatiku BiH, 27(4), 253–258. https://doi.org/10.5455/aim.2019.27.253-258

NXP. (2012). Blood Pressure Monitor Fundamentals and Design. Disponible en: https://www.nxp.com/docs/en/applicationnote/AN4328.pdf

OCEANO. (1996). Autodicactica oceano color volumen VI. Barcelona, Barc: OCEANO GRUPO EDITORIAL ISBN: 84-7764-930-8.

Onion Corporation. (2020). Onion Omega 2 Documentation. Disponible en: https://docs.onion.io/omega2-docs/omega2p.html

Ordunez, P. (2018). Hearts in the Americas: Hearts en Cuba. TEMAS DE SALUD. http://temas.sld.cu/hipertension/tag/oms/

Rodrigues, J. J. et al. (2018). "Enabling Technologies for the Internet of Health Things," in IEEE Access, vol. 6, pp. 13129-13141, 2018, doi: 10.1109/ACCESS.2017.2789329.

Vélez, A. (2019). Arquitecturas de referencia para IoT con trasnferencia segura de información. (Tesis en Especialización De Seguridad Informática), Escuela De Ciencias Básicas, Tecnlogía e Ingeniería, Universidad Nacional abierta y a diastancia, Tulua.

Statistics

Abstract
0
PDF accesses
0

Dimensions

PlumX


Downloads

Download data is not yet available.